Test strips

WH Accu TestTM

WH Accu TestTM  One-step Pregnancy Test

The WH Accu Test one-step pregnancy test is a rapid qualitative one-step assay for detection of hCG in urine. The method employs a unique combination of monoclonal dye conjugate and polyclonal slid phase antibodies to selectively identify the hCG in the test samples with an extremely high degree of sensitivity. In less than 5 minutes, levels of hCG as low as 25mlU/ml can be detected. Each one-step pregnancy test strip is individually sealed in a foil pouch with a desiccant inside. Foil pouch strips can be stored at room temperature. Period of expiration is 18 months. This test can be used as early as the first day of missing period. And test can be done at any time of the day. The result can easily be read in 3 minutes. Its accuracy is over 99%.

Product Number

Description

Test Kits Per Box

F1-DK04

HCG Pregnancy Test Strip 50/box

50

F1-CK04

Hcg Pregnancy Urine Device/Cassette 25/box

25

F1-M07

Urine Pregnancy Midstream Test

1

F1-DCK1

HCG Pregnancy Test Card 25/box

25

F2-DCK4

Combo Pregnancy Test Strip 50/box

50

F2-CK04

Combo Pregnancy Test Device/Cassette 25/box

25

 

 

 

WH OvultellTM

WH OvultellTM  One-step Ovulation Test

The WH Ovultell one-step ovulation predictor is a qualitative immunoassay and employs a unique combination of monoclonal and polyclonal antibodies to selectively identify LH in test samples with a high degree of sensitivity.  Its accuracy is over 99%.

This test is for women who are:

   ü Trying to become pregnant.

   ü Having irregular menstrual cycle.

   ü Having difficulty to become pregnant.

Product Number

Description

Test Kits Per Box

F3-DK05

Ovultell Dip Single Card 40/box

40

F3-CK05

Ovultell Test Device/Cassette 40/box

40

 

 

         Spectrophotometers

The UNICO 1000 Precisely designed and ruggedly built, this easy-to-use spectrophotometer is ideal for student use in high schools and colleges. It is suitable for general analysis and experiments such as Beer-Lambert, Absorption Spectrum, Chlorophyll, protein (biuret test) more.

 

 

 

 

Features
 

  • Dynamic Range of 400-1000 nm

  • Built-in secondary filters reduce stray light and increase precision.

  • The student-proof positive safety stopper integrated with the wavelength dial prevents damage to the monochromator and grating.

  • Large digital display

  • Analog interface with external analog device.

  • Comes with 1/2 inch round tube holder, 10 mm square cuvette adapter, box of 12 round tubes

  • 110 V and 220V switchable

  • Fully packed and ready to use.

 

Specifications

Model 1000

Bandpass

20 nm

Monochromator

Single Beam, Grating System 1200 lines/mm

Wavelength Range

400-1000 nm

Wavelength Accuracy

±3 nm

Wavelength Repeatability

±1 nm

Stray Light

2%T at 400 nm

Photometric Range

0-100%T
0-1.99A

Photometric Accuracy

± 2.0T%

Data Output

Analog Output

Light Source

Tungsten Halogen Lamp

Power Requirements

110V/50Hz, 230V/60Hz
switchable

Size

16 x 12 x 8 inch
(406 x 305 x 203mm)

Shipping Size

19.5 x 16.1 x 11.3 inch
(496 x 410 x 286 mm)

Weight

14 lbs (6.3 kg)

Shipping Weight

16 lbs (7.3 kg)


 

2100 series

The UNICO Model 2100 series are high performance, user-friendly UV/Vis spectrophotometers specially designed for the rigorous, day-to day demands of today's laboratory. The state-of-art electronic design and high speed digital processing system guarantee users with fast and powerful data processing and reduce the noise to minimum. The rugged-constructed metal platform ensures durability and stability, unparalleled in the market

UNICO 2100 series adopt a sealed high-precision optical system design assuring a bandpass narrower than 5 nm and minimize the stray light. The measurement accuracy is maintained over the entire wavelength range.

Features
 
  • Dynamic Range of 325/200-1000 nm
     
  • Digital display of photometric result
     
  • Easy operation
  • Auto zero function
     
  • Flexible Sample Compartment
     
  • Solid State Detector for entire wavelength range
     
  • Built-in filters to ease operation
     
  • Complete Accessories for easy instrument operation
     
  • Optional Application Software Package
     
  • Peltier/Zipper Package for flowthru and continuous temperature control from 15°C to 40°C
Specifications Model 2100 Model 2100UV
Bandpass 5 nm 5 nm
Monochromator Single Beam, Grating System 1200 lines/mm Single Beam, Grating System 1200 lines/mm
Wavelength Range 325-1000 nm 200-1000 nm
Wavelength Accuracy ±2 nm ±2 nm
Wavelength Repeatability ±1 nm ±1 nm
Stray Light < 0.3%T at 340 & 400 nm < 0.3%T at 220 & 340 nm
Photometric Range 0-125%T
0-2.5A
0-1999C (0-1999F)
0-125%T
0-2.5A
0-1999C (0-1999F)
Photometric Accuracy ±0.004A at 0.5A ±0.004A at 0.5A
Display and Data Output Two line, 9-LED/RS232C Two line, 9-LED/RS232C
Light Source Tungsten Halogen Lamp Tungsten Halogen/Deuterium  Lamp
Power Requirements 110V/50Hz,  230V/60Hz, switchable 110V/50Hz,  230V/60Hz, switchable
Cuvette Holder 4-position Cuvette Holder 4-position Cuvette Holder
Working Temperature 5°C to 3°5C 5°C to 3°5C
Humidity Range less than 85% less than 85%
Size 18.5 x 15.7 x 5.5 inch
(470 x 400 x 140 mm)
18.5 x 15.7 x 5.5 inch
(470 x 400 x 140 mm)
Shipping Size 22.4 x 19.7 x 11.4 inch
(570 x 500 x 290 mm)
22.4 x 19.7 x 11.4 inch
(570 x 500 x 290 mm)
Weight 26 lbs (11.8 kg) 32 lbs (14.5 kg)
Shipping Weight 29 lbs (13.2 kg) 35 lbs (15.9 kg)

Accessories

Parts Number
UNICO Model 2100 Series Order Item Number

Cuvette
UNICO Model 2100 Series Cuvette Order Item Number

Application Software Package
UNICO UV-2100 Spectrophotometer SB-2.10

Optional Holders
Cuvette Holder and Cuvette Holder Package

 

Spinreact  Kits.
• Serology

• Clinical Biochemistry

• Immunochemistry

• Rapid test "One step"

• Blood grouping

• Coagulation

• Electrophoresis

• Instruments

• Drugs of abuse EIA
 
 

Item

Ref

TEST PARAMETERS

Uro

Glu

Bili

Ket

S.G

Blo

pH

Pro

Nit

Leu

As

Com. Arrea

CYBOW G

0011

 

v

 

 

 

 

 

 

 

 

 

 

CYBOW 2GP

0021

 

v

 

 

 

 

 

v

 

 

 

 

CYBOW 3

0031

 

v

 

 

 

 

v

v

 

 

 

 

CYBOW 4

0041

 

v

 

 

 

v

v

v

 

 

 

 

CYBOW 5

0051

 

v

 

v

 

v

v

v

 

 

 

 

CYBOW 6

0061

 

v

v

v

 

v

v

v

 

 

 

 

CYBOW 7

0071

v

v

v

v

 

v

v

v

 

 

 

 

CYBOW 8

0081

v

v

v

v

 

v

v

v

v

 

 

 

CYBOW 9

0091

v

v

v

v

v

v

v

v

v

 

 

 

CYBOW 10

0101

v

v

v

v

v

v

v

v

v

v

 

 

CYBOW 11

0111

v

v

v

v

v

v

v

v

v

v

v

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CYBOW 10

1101

v

v

v

v

v

v

v

v

v

v

 

v

CYBOW 11

1111

v

v

v

v

v

v

v

v

v

v

v

v

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 Keto Slim

0019

 

 

 

 

 

 

v

 

 

 

 

 

* Item (Ref. no. : 1101 & 1111) are the strips for Visual test or for CYBOW Reader 720
* Item (Ref. no : 0019) is urine strips for Diet Test.
* The other Items are for Visual test or for CYBOW Reader 100 plus & CYBOW Reader 300
* Any other optional items (combinations) on your demand could be available.

 

 

 

 

CYBOW Reagent Strips are qualitative and semi-quantitative. The methodology references are NCCLS (National Committee for Clinical Laboratory Standard) EP9-A2 and NCCLS EP 10-A.

Analyte

Unit

Lab Assay Range

(NCCLS)

Reportable Range

(CYBOW)

Urobilinogen

µmol/L

0.2 - 300

33 - 131

Glucose

µmol/L

0 - 300

0 - 55

Bilirubin

µmol/L

0 - 313

0 - 50

Ketone

µmol/L

0.02 - 35

0 - 10

Specific Gravity

-

1.000 - 1.040

1.000 - 1.030

Blood

RBC/µL

0 - 350

0 - 250

pH

-

0 - 14.0

5.0 - 9.0

Protein

g/L

0.003 - 50

0 - 10

Nitrite

µmol/L

1.0 - 400

Neg - Pos

Leukocytes

WBC/µL

0 - 800

0 - 500

Ascorbic Acid

mmol/L

0.1 - 14.0

0 - 2.4

 

  The lowest  concentration of analytical sensitivity that can be distinguished from Negative

TEST Pad

Sensitivity (Specificity)

Urobilinogen

2 EU/ dL(Urobilinogen)

Glucose

50 mg/dL(Glucose)

Bilirubin

0.5 mg/dL (Bilirubin)

Ketone

5 mg/dL (Acetoacetic acid)

Blood

10 RBC/µL (Intact and lysed RBC)

Protein

10 - 15 mg/dL (albumin)

Nitrite

0.05 mg/dL (Nitrite ion)

Leukocytes

20 - 25 WBC/µL

Ascorbic Acid

20 mg/dL (Ascorbic acid)

 

 

 