HKN-93A

INFANT RADIANT WARMER
State Food and Drug Administration 2005 No.: 3540553
CMDC TUV ISO9001 ISO13485 CE0123

Brief introduction:
servo-controlled by micro-computer with option of automatic control or manual control the
temperature; skin temperature sensor and bed temperature sensor; touch switch panel, setting
temperature, real temperature, and APGAR timer can display separately, heating power rate
indicates 0-100%; multi-function self-checking alarms; horizon angle of radiant head can be
adjusted in two ways, there are 2pcs of radiant boxes; inclination of bassinet is adjustable;
x-ray cassette is under the bed; 2pcs of oxygen cylinders and oxygen infusion
device; RS232 connector, data output.
Standard configure:
radiation head, blue light radiant box (2pcs), temperature controller, skin temperature sensor
, bed temperature sensor, infant bed, I.V. Pole, tray, x-ray cassette, oxygen cylinders, oxygen
infusion device, low-pressure aspirator, resuscitation bag, infant head fixing frame, Stand.
Technical specification:
Power supply : AC220V 50HZ
Power input: 950VA
Temperature control range:25℃~37℃
Sensor precision: ≤0.3℃
Uniformity of bed temperature: ≤2.0℃
Adjustment angle for the radiation head :0°,30°,60
inclination of infant bed: ±15°
APGAR Timer: it has sound indication in 1min, 5min, 10min.

Alarming:
with audible and visible alarm, and it can indicate the real temperature and cut off the power supply of heater;
Over-temp alarm: when the skin temperature >39.5℃;
Deviation alarm: indication temperature deviates away the setting temperature ±1℃;
Sensor alarm: when the sensor is disconnected, open circuit, short circuit or put on the outside of bed;
Power failure alarm: when start up the unit, but there is no power and the power cord is disconnected.
System alarm: when there is system malfunction inside of temperature controller.
Package:
Gross Weight:150Kg
Measurement:1270mm×810mm×1110mm


XHZ

NEONATE BILIRUBIN PHOTOTHERAPY EQUIPMENT
ZJFDA(Z) Z 2007 No.: 2260333
CMDC TUV ISO9001 ISO13485
Brief introduction:

Temperature servo-controlled by micro-computer, and this unit Adopts the far-infrared ceramic
heating plate as heating resource, has the function of over-temp alarm and sensor alarm; blue
light in double way, there are total 11 pieces of blue lamp with 20W for each; touched operation
panel,LCD can display clock and temperature with blue light timer; and inside of box, there is
heat-dissipating fan; the infant bed is made of whole transparent acryl plastic, and the panels
around the bed can be opened, and the infant bed can be pulled out from the side door.

Standard configure:
Temperature controller, Up Cabinet, Cabinet, infant bed, I.V.Pole.

Technical specification:
Power supply : AC220V 50HZ
Power input: 800VA
Temperature control range: 25℃~37℃
The margin between the indication temperature and the control temperature: ≤0.7℃
Uniformity of the surface temperature on bed: ≤3.5℃
Radiation of Blue light for upper radiant box:≥850μW/cm2
Radiation of Blue light for lower radiant box:≥700μW/cm2
Timer range of blue light:0~9999 hours ( Reset )
Over temperature alarm: ≤39.5℃, give the visible and audible alarm
Sensor Alarm: The leads of sensor plug is open circuit or close circuit.

Package:
Gross Weight:Main body 70Kg / Cabinet 50Kg
Measurement:Main body 1000mm×700mm×790mm
                             Cabinet 910mm×600mm×990m


XHZ-90


NEONATE BILIRUBIN PHOTOTHERAPY EQUIPMENT
ZJFDA(Z)Z 2005 No.: 2260262
CMDC TUV ISO9001 ISO13485

Brief introduction:
The pillar is made of stainless steel, has the variable height adjustment mechanism and swivel castors
with brake; can be equipped with the infant incubator or the infant bed; and the angle of radiant
box can be adjusted, inside of this box, there are 5 pieces of blue lamp with 20W for each; LCD
display Timer can record the treatment time or the using time for the lamp accurately.

Standard configure:
Radiant box, pillar, lift pole, stand.

Technical specification:
Power supply : AC220V 50HZ
Power input: ≤100VA
Blue light wavelength:420nm~470nm
Average radiation of blue light:≥500μW/cm2
Adjustment height for the radiation box:1350mm~1650mm
Timer range of blue light:0~9999 hours ( Reset )

Package:
Gross Weight:23Kg
Measurement:955mm×655mm×205mm


YP-100


INFANT INCUBATOR
State Food and Drug Administration 2005 No.: 3540651
CMDC TUV ISO9001 ISO13485 CE0123
Brief introduction:
servo-controlled by micro-computer; quite operation windows can reduce the disturbance
to the baby during nursing; touch switch panel with LED digital display, set-temp,
real-temp are displayed separately; multiply self-checking alarms with audible and visible;
heating power rate indicates 0-100%.

Standard configure:
Hood, infant bed, temperature controller, water tank, air filter, blue light radiant box, I.V. Pole, stand.

Technical specification:
Power supply : AC220V,50HZ
Power input: 600VA
Air Temperature control range:25℃~37℃
Changing of temperature: ≤0.5℃
Uniformity of temperature: ≤0.8℃
Temperature rising time: ≤45min
Noise level: ≤55dB(A)
Alarming:
audible and visible alarm indication, and it can indicate the real temperature and cut off the power
supply of heater. Over-temp alarm: when the temperature control ≤38℃;
Deviation alarm:±3℃;
Sensor alarm: when the sensor is disconnected, open circuit, short circuit or put on the wrong place;
Fan alarm: when the fan is blocked, speed ≤1000rpm or stop working;
Power failure alarm: when there is no power or the power cord is disconnected.
System alarm: when there is E2ROM malfunction inside of temperature controller.
Package:
Gross Weight:72Kg
Measurement:1085mm×640mm×1065mm


YP-100A


INFANT INCUBATOR
State Food and Drug Administration 2005 No.: 3540651
CMDC TUV ISO9001 ISO13485 CE0123

Brief introduction:
servo-controlled by micro-computer; quite operation windows can reduce the disturbance
to the baby during nursing; touch switch panel with LED digital display, set-temp,
real-temp are displayed separately; multiply self-checking alarms with audible and
visible; heating power rate indicates 0-100%; the infant bed can be pulled out from the
side door

Standard configure:
Hood, infant bed, temperature controller, water tank, air filter, I.V. Pole, stand.

Technical specification:

Power supply : AC220V,50HZ
Power input: 600VA
Air Temperature control range:25℃~37℃
Changing of temperature: ≤0.5℃
Uniformity of temperature: ≤0.8℃
Temperature rising time: ≤45min
Noise level: ≤55dB(A)
Alarming:
audible and visible alarm indication, and it can indicate the real temperature and cut off
the power supply of heater.
Over-temp alarm: when the temperature control ≤38℃;
Deviation alarm:±3℃;
Sensor alarm: when the sensor is disconnected, open circuit, short circuit or put on the wrong place;
Fan alarm: when the fan is blocked, speed ≤1000rpm or stop working;
Power failure alarm: when there is no power or the power cord is disconnected.
System alarm: when there is E2ROM malfunction inside of temperature controller.
Package:
Gross Weight:72Kg
Measurement:1085mm×640mm×1065m


YP-100AB


INFANT INCUBATOR
State Food and Drug Administration 2005 No.: 3540651
CMDC TUV ISO9001 ISO13485 CE0123
Brief introduction:
servo-controlled by micro-computer; quite operation windows can reduce the
disturbance to the baby during nursing; touch switch panel with LED digital
display, set-temp, real-temp are displayed separately; multiply self-checking
alarms with audible and visible; heating power rate indicates 0-100%; the
infant bed can be pulled out from the side door; blue light radiant box can
give the baby jaundice phototherapy treatment when keeping warm on baby with
blue light timer.

Standard configure:
Hood, infant bed, temperature controller, water tank, air filter, blue light radiant box, I.V. Pole, cabinet.
Technical specification:
Power supply : AC220V,50HZ
Power input: ≤600VA
Temperature control range:25℃~37℃
Changing of temperature: ≤0.5℃
Uniformity of temperature: ≤0.8℃
Temperature rising time: < 45 min
Noise level: ≤55dB(A)
Average radiation of blue light: ≥500μW/cm2
Timing range of blue light timer:0~9999 hour 59 minutes
Accumulative error of blue light timing:≤0.002%
Alarming:
audible and visible alarm indication, and it can indicate the real temperature and cut off the
power supply of heater.
Over-temp alarm: when the air temperature control ≤38℃;
Deviation alarm: air temperature control ±3℃;
Sensor alarm: when the sensor is disconnected, open circuit, short circuit or put on the wrong place;
Fan alarm: when the fan is blocked, speed ≤1000rpm or stop working;
Power failure alarm: when there is no power or the power cord is disconnected.
System alarm: when there is E2ROM malfunction inside of temperature controller.

Package
Gross Weight:83Kg
Measurement:1085mm×640mm×1110mm


YP-100B


INFANT INCUBATOR
State Food and Drug Administration 2005 No.: 3540651
CMDC TUV ISO9001 ISO13485 CE0123
Brief introduction:
servo-controlled by micro-computer; quite operation windows can reduce the
disturbance to the baby during nursing; touch switch panel with LED digital display, set-temp
, real-temp are displayed separately;
multiply self-checking alarms with audible and visible; heating power rate
indicates 0-100%; blue light radiant box can give the baby jaundice phototherapy
treatment when keeping warm on baby with blue light timer.

Standard configure:
Hood, infant bed, temperature controller, water tank, air filter, blue light radiant box, I.V. Pole, stand.
Technical specification:
Power supply : AC220V,50HZ
Power input: ≤600VA
Temperature control range:25℃~37℃
Changing of temperature: ≤0.5℃
Uniformity of temperature: ≤0.8℃
Temperature rising time: < 45 min
Noise level: ≤55dB(A)
Average radiation of blue light: ≥500μW/cm2
Timing range of blue light timer:0~9999 hour 59 minutes
Accumulative error of blue light timing:≤0.002%
Alarming:
audible and visible alarm indication, and it can indicate the real temperature and cut off the
power supply of heater.
Over-temp alarm: when the air temperature control ≤38℃;
Deviation alarm: air temperature control ±3℃;
Sensor alarm: when the sensor is disconnected, open circuit, short circuit or put on the wrong place;
Fan alarm: when the fan is blocked, speed ≤1000rpm or stop working;
Power failure alarm: when there is no power or the power cord is disconnected.
System alarm: when there is E2ROM malfunction inside of temperature controller.

Package:
Gross Weight:83Kg
Measurement:1085mm×640mm×1110mm


 

 

 